ONLINE UPS E² Series 1KVA 1PH:1PH 36V
sawan26
Microtek High Frequency Online UPS provides Uninterrupted Pure Power for Critical Applications such as Computer Network, Servers, Cyber Cafes, and CCTV Camera etc. E2 Series Ensures Syschronization of the hardware, Software, analytics and ongoing services to ensure its customers vital applications run continously, perform optimally as per the requirement. this series is based on high frequency dobule convertion IGBT technology with static bypass which improves reliablility and operates with configurable output voltage settings.
SALIENT FEATURES
- Inbuilt OVCD (Over Voltage Cut-Off Device) with Surge Protection.
- Static Bypass-improves Reliability & Alarm (Optional) for Mute Mode.
- Smart LCD Display for Real-time information.
- SNMP Card (Optional) on demand.
- EMI Noise Filter With Isolation Transformer (Optional).
- Efficient Micro Controller based.
- Over Temperature Indication & Protection.
- Advanced PFC Technology & Generator Compatible.
- Robust Product-improves Power Quality with Reliability.
- Configurable Output Voltage settings & External Charger up to 8 Amps.
- Output Frequency fixed at 50Hz or can synchronized with Input Frequency.
WEIGHT4.08kg
DIMENSIONS (L W H)14.5x28.2x22
GENRAL INFORMATION
MODEL NAME / NUMBER - ONLINE UPS E² / NM36EM1KK11
CAPACITY - 1KVA/80W
DC VOLTAGE SYSTEM - 36 VDC
INPUTINPUT
VOLTAGE RANGE - 110VAC+5% - 300VAC+5%
FREQUENCY RANGE 40Hz - 70Hz
PHASE SINGLE PHASE WITH GROUND
POWER FACTOR >0.99 @ FULL LOAD
OUTPUTOUTPUT
VOLTAGE 200/ 208/ 220/ 230/ 240VAC
AC VOLTAGE REGULATION +1% (Battery Mode)
FREQUENCY RANGE (Battery Mode) 50Hz+0.25Hz OR 60Hz+0.3Hz
CURRENT CREST RATIO 3:1
HARMONIC DISTORTION
• <2% THD (Linear Load)
• 4% THD (N on-Linear Load)
OVERLOAD CAPABILITY
• 105%-110%: UPS SHUTS DOWN AFTER 10 MINUTES AT BATTERY MODE OR TRANSFER TO BYPASS WHEN THE UTILITY IS NORMAL.
• 110%-130%: UPS SHUTS DOWN AFTER 1 MINUTE AT BATTERY MODE OR TRANSFER TO BYPASS WHEN THE UTILITY IS NORMAL.
• >130%: UPS SHUTS DOWN AFTER 3 SECONDS AT BATTERY MODE OR TRANSFER TO BYPASS WHEN THE UTILITY IS NORMAL.
TRANSFER TIME
AC MODE TO BATTERY MODE 0/ INVERTER TO BYPASS: <4ms (Typical 2.5ms)
WAVEFORM (Battery Mode) PURE SINEWAVE
EFFICIENCY
EFFICIENCY (AC MODE / BATTERY MODE) 88% / 83%
BATTERY
CHARGING CURRENT 6A
ENVIRONMENT
OPERATING HUMIDITY / TEMP. 20-95% RH @ 0-40°C (N on-Condensing)
NOISE LEVEL LESS THAN 50dBA @ 1 METER (WITH FAN SPEED CONTROL)
DISPLAY - LCD DISPLAY INDICATIONS
MANAGEMENTSNMP (OPTIONAL) POWER MANAGEMENT FROM SNMP MANAGER & WEB BROWSER
?